[New Function] | ◆ Substantial maintenance reduction by eliminating lens cleaning |
---|---|
[Improvement] | ◆ Increased accuracy (*from existing LED type sensor (SN-GCHA1)) ◆ Mass-density numerical display (μg/m3) without using external MCU ◆ Capable of visualizing IAQ (indoor air quality) |
Overview
PM2.5 Sensor Overview
- High SN by optimized optical design makes high-detectability of micro-particles.
- High-accurate conversion to mass-density value (μg/m3) by advanced algorithm.
- Built-in MCU, no need for external MCU.
- Unique internal fluid design has eliminated lens cleaning (*Fig. 1)
- Reduced stabilization time after starting (*Fig. 2)
Application
- Visualization of the air cleaning function of air purifiers and air-conditioners
- IAQ management for HEMS / BEMS
※HEMS:Home Energy Management System
BEMS:Building Energy Management System - Installation where maintenance cannot be provided
Fig. 1: Unique internal fluid design eliminated lens cleaning

Fig. 2: Reduced stabilization time after starting

PM2.5 Sensor Specification
SN-GCJA6 | ||
---|---|---|
Appearance | ![]() (Mass production started in Feb. 2021) |
|
Type | LED Type | |
Detectable Objects & Accuracy | PM1.0 | - |
PM2.5 | 35~100μg/m3:±15μg/m3 100~600μg/m3:±15% |
|
PM10 | - | |
Pollen | × | |
Concentration range | 1~600ug/m3 | |
Operating life | 7 years | |
Size (width, depth, height) | 30×28×30mm | |
Output format | UART&I2C | |
Operating power voltage | 5.0V(±10%) | |
Consumption current | Below 100mA | |
Airflow control | Heater resistance type | |
Maintenance (lens cleaning) | Not required |