- ◆ Capable of visualizing IAQ (indoor air quality、μg/m3 )
- ◆Compared with the LED type, the laser type provides higher accuracy and stabilization

Overview
Laser type PM sensor product outline
- Smaller size (37 x 37 x 12mm)
- Better accuracy (±10%) from low to high concentrations(1,000μg/m3 )
- Longer life-time by optimizing electrical/SW control
- Auto calibration function
- Less dust-accumulation structure for minimizing electrical tracking
Application
- For home appliance products and/or air quality monitors which need more accuracy & further advantages to the competitor's
Principal features of laser type sensor
Compact-sizing of37×37×12mm achieved
Measurement from low to high concentration (up to 1,000μg/m3) with ±10% accuracy.
Suppression of sensor interior contamination by using a tracking prevention structure.
Monitoring electronic components and optimizing by electrical control
Longer life and maintaining accuracy until latter half of life Laser type PM sensor specification
| SN-GCJA5 | ||
|---|---|---|
| Appearance | ![]() |
|
| Type | Laser type | |
| Detectable Objects & Accuracy | PM1.0 | Measurable |
| PM2.5 | 35~1000μg/m3:±10% | |
| PM10 | ±10% | |
| Pollen | × | |
| Concentration range | 1~1000ug/m3 | |
| Operating life (accuracy continuation period) | 5 years | |
| Size (width, depth, height) | 37×37×12mm | |
| Output format | UART&I2C | |
| Operating power voltage | 5.0V(±10%) | |
| Consumption current | Below 100mA | |
| Airflow control | DC fan motor | |
| Maintenance (lens cleaning) | Not required | |
Related information
[Specifications]
Inquiries
Buy or Sample
Samples can be purchased from the link below.
| Sample | Digi-Key Electronics | Mouser Electronics |
|---|---|---|
|
Laser Type PM Sensor |
||
|
Laser Type PM Sensor (with cable) |
Click here to make inquiries