Compact size (PS type)
Precision semiconductor pressure sensor that contributes to downsizing of the apparatus.
Pressure type
・Standard type(with glass base) : Rated pressure 4.9 kPa to 980.7 kPa
・Economy type(without glass base) : Rated pressure 40 kPa
・Standard type(with glass base) : Rated pressure 4.9 kPa to 980.7 kPa
・Economy type(without glass base) : Rated pressure 40 kPa
Topics
- 2025-11-04 PS series have been discontinued.
- 2023-11-21 PS series is NOT Recommended for New Design.
- 2021-04-01 Some parts of PS Pressure Sensors are Not Recommended for New Design (12 part numbers).
- 2016-10-28 Registration certificates of quality and environment certifications (ISO, TS) are available for download
Basic Information
High precision pressure sensor (without amp.)


Features
-
Ultra-miniature size: much more compact than the PF pressure sensors offered in the past
- Base area:7.2(W)×7.2(D) mm .283(W) × .283(D) inch
- Only 60% in mounting area and 91% in overall height of previous models (PF)

-
High-level precision and linearity
A high degree of precision and linear detector response have been achieved by applying the semiconductor strain gauge system. Highly reproducible based on repeated pressure.
-
Impressive line-up of models
- Taking their place alongside the standard 5kW bridge resistance models are those with a 3.3kW resistance which is optimally suited to 5V drive circuits.
- Economy model (no glass base) gives outstanding value for customer appliances 40kPa(0.4kgf/cm2) and 49kPa(0.5kgf/cm2) units are also available.
-
Improved ease of DIP pin insertion into printed circuit boards
- The ends of the DIP pins are chamfered to ensure easy insertion into printed circuit boards.
Example of pressure characteristics
(when the rated pressure is between
98.1 kPa{1.0kgf/cm2})Drive current: 1.5 mA rated current; ambient temperature: 25°C 77°F

Cross-section of Sensor Chip
Appllications
- Industrial use: pressure switches and pneumatic components, compressed air pressure measuring devices and airbeds
- Medical use: blood pressure meters, oxygen generator and airbeds
- Others: pressure sensing devices for air pressure mediums
Rating/Performance
Standard (With glass base)
| Type of pressure | Gauge pressure | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Pressure medium | Air (For other medium, please consult us.) | |||||||||||
| Rated pressure | Unit: kPa | 4.9 | 34.3 | 49.0 | 98.1 | 196.1 | 343.2 | 490.3 | 833.6 | 980.7 | 98.1 | 980.7 |
| Max. applied pressure | Twice the rated pressure | 1.5 times the rated pressure | Twice the rated pressure | 1.5 times the rated pressure | ||||||||
| Bridge resistance | 5,000±1000ohm | 3,300±700ohm | ||||||||||
| Ambient temperature | -20 to +100°C -4 to +212°F(no freezing or condensation) | |||||||||||
| Storage temperature | -40 to +120°C -40 to +248°F(no freezing or condensation) | |||||||||||
| Standard temperature | 25°C 77°F | 30°C 86°F | ||||||||||
| Temperature compensation range | 0 to 50°C 32 to 122°F | 0 to 60°C 32 to 140°F | ||||||||||
| Drive current (constant current) | 1.5 mA DC | 1.0 mA DC | ||||||||||
| Output span voltage | 40±20 mV | 100±40 mV | 65±25 mV | |||||||||
| Offset voltage | ±20 mV | |||||||||||
| Linearity | ±0.7%FS | ±0.3%FS | ±0.5%FS | ±0.6%FS | ±1.0%FS | |||||||
| Pressure hysteresis | ±0.6%FS | ±0.2%FS | ±0.4%FS | ±1.0%FS | ||||||||
| Offset voltage-temperature characteristics (0 to 50°C 32 to 122°F) | ±15%FS | ±5.0%FS | ±3.5%FS | |||||||||
| Sensitivity-temperature characteristics (0 to 50°C 32 to 122°F | ±10%FS | ±2.5%FS | ||||||||||
- Unless otherwise specified, measurements were taken with a drive current of ±0.01 mA and humidity ranging from 25% to 85%.
- Please consult us if a pressure medium other than air is to be used.
- This is the regulation which applies within the compensation temperature range.
- Please consult us if the intended use involves a negative pressure.
Economy type (Without glass base)
| Type of pressure | Gauge pressure | |
|---|---|---|
| Pressure medium | Air (For other medium, please consult us.) | |
| Rated pressure | Unit: kPa | 40.0 |
| Max. applied pressure | Twice the rated pressure | |
| Bridge resistance | 3,300± 600ohm | |
| Ambient temperature | -5 to +50°C +23 to +122°F | |
| Storage temperature | -20 to +70°C -4 to +158°F | |
| Standard temperature | 25°C 77°F | |
| Temperature compensation range | 5 to 45°C 41 to 113°F | |
| Drive current (constant current) | 1.5 mA DC | |
| Output span voltage | 43.5±22.5 mV | |
| Offset voltage | ±15 mV | |
| Linearity | ±0.3%FS | |
| Pressure hysteresis | ±0.7%FS | |
| Offset voltage-temperature characteristics (0 to 50°C 32 to 122°F) | ±10%FS | |
| Sensitivity-temperature characteristics (0 to 50°C 32 to 122°F) | ±1.3%FS | |
- Unless otherwise specified, measurements were taken with a drive current of ±0.01 mA and humidity ranging from 25% to 85%.
- Please consult us if a pressure medium other than air is to be used.
- This is the regulation which applies within the compensation temperature range.
- Please consult us if the intended use involves a negative pressure.
Dimensions
Unit: mm inch
- Terminal direction: DIP terminal Direction opposite the pressure inlet direction ADP41**
- Terminal direction: DIP terminal Pressure inlet direction ADP42**
- Terminal direction: SMD terminal ADP4932, ADP4933
1.Terminal direction: DIP terminal Direction opposite the pressure inlet direction ADP41**
Dimensions
Tolerance: ±0.3 ±.012

Recommended PC board pattern
(BOTTOM VIEW)
Terminal connection diagram
| Terminal No. | Name |
|---|---|
| 1 | Power supply (+) |
| 2 | Output (+) |
| 3 | Power supply (-) |
| 4 | Power supply (-) |
| 5 | Output (-) |
| 6 | No connection |
*Leave terminal 6 unconnected.
2.Terminal direction: DIP terminal Pressure inlet direction ADP42**
Dimensions
Tolerance: ±0.3

Recommended PC board pattern
(BOTTOM VIEW)
Terminal connection diagram
| Terminal No. | Name |
|---|---|
| 1 | Power supply (+) |
| 2 | Output (+) |
| 3 | Power supply (-) |
| 4 | Power supply (-) |
| 5 | Output (-) |
| 6 | No connection |
*Leave terminal 6 unconnected.
3.Terminal direction: SMD terminal ADP4932, ADP4933
Dimensions
Tolerance: ±0.3

Recommended PC board pattern
(BOTTOM VIEW)
Terminal connection diagram
| Terminal No. | Name |
|---|---|
| 1 | Power supply (+) |
| 2 | Output (+) |
| 3 | Power supply (-) |
| 4 | Power supply (-) |
| 5 | Output (-) |
| 6 | No connection |
*Leave terminal 6 unconnected.