・Standard type(with glass base) : Rated pressure 4.9 kPa to 980.7 kPa
・Economy type(without glass base) : Rated pressure 40 kPa
Topics
- 2023-03-31 Some parts of PF Pressure Sensors has been discontinued.
- 2023-11-21 PF series is NOT Recommended for New Design.
- 2021-04-01 Some parts of PF Pressure Sensors are Not Recommended for New Design (12 part numbers).
- 2016-10-28 Registration certificates of quality and environment certifications (ISO, TS) are available for download
Basic Information
High precision pressure sensor (without amp.)
Features
-
A wide range of rated pressure, including a minute pressure
There are 10 types of sensors covering a wide range of rated pressure from a minute pressure between 4.9kPa {0.05kgf/cm2}, to a maximum pressure of 980.7kPa {10kgf/cm2}.
-
Highly accurate, linear characteristics
This sensor employs a semiconductor strain gauge method, ensuring accurate and linear detection characteristics. It also has excellent repeatability of pressure characteristics.
-
Impressive line-up of models
- Taking their place alongside the standard 5kohm bridge resistance models are those with a 3.3kohm resistance which is optimally suited to 5V drive circuits.
- Economy model (no glass base) gives outstanding value for consumer appliances 40kPa (0.4kgf/cm2) and 49kPa (0.5kgf/cm2) units are also available.
Example of pressure characteristics (ADP1141)
Drive current: 1.5 mA rated current; ambient temperature: 25°C 77°F
Cross-section of Sensor Chip
Appllications
- Industrial use: pressure switches and pneumatic components, compressed air pressure measuring devices and airbeds
- Medical use: blood pressure meters, oxygen generator and airbeds
- Others: pressure sensing devices for air pressure mediums
Rating/Performance
Standard type (With glass base)
Type of pressure | Gauge pressure | |||
---|---|---|---|---|
Pressure medium | Air (For other medium, please consult us.) | |||
Rated pressure | Unit: kPa | 490.3 | 833.6 | 980.7 |
Max. applied pressure | Twice the rated pressure | 1.5 times the rated pressure | ||
Bridge resistance | 5,000±1,000ohm | |||
Ambient temperature | -20 to +100°C -4 to +212°F(no freezing or condensation) | |||
Storage temperature | -40 to +120°C -40 to +248°F(no freezing or condensation) | |||
Temperature compensation range | 0 to 50°C 32 to 122°F | |||
Drive current (constant current) | 1.5 mA DC | |||
Output span voltage | 100±40 mV | |||
Offset voltage | ±20 mV | |||
Linearity | ±0.5%FS | ±0.6%FS | ||
Pressure hysteresis | ±0.4%FS | |||
Offset voltage-temperature characteristics (0 to 50°C 32 to 122°F) |
±5.0%FS | |||
Sensitivity-temperature characteristics (0 to 50°C 32 to 122°F |
±2.5%FS |
- Unless otherwise specified, measurements were taken with a drive current of1.5 mA ±0.01 mA at a temperature of 25°C 77°F and humidity ranging from 25% to 85%.
- Please consult us if a pressure medium other than air is to be used.
- This is the regulation which applies within the compensation temperature range.
- Please consult us if the intended use involves a negative pressure.
Dimensions
Unit: mm inch
- Terminal direction: DIP terminal Direction opposite the pressure inlet direction ADP11**(*)
- Terminal direction: DIP terminal Pressure inlet direction ADP12**(*)
1. Terminal direction: DIP terminal Direction opposite the pressure inlet direction ADP11**(*)
Dimensions
General tolerance: ±0.3 ±.012
Recommended PC board pattern
( BOTTOM VIEW )
Tolerance: ±0.1 ±.004
Terminal connection diagram
Terminal No. | Name |
---|---|
1 | Output (-) |
2 | Power supply (+) |
3 | Output (+) |
4 | No connection |
5 | Power supply (-) |
6 | Output (-) |
*Leave terminal 4 unconnected.
2. Terminal direction: DIP terminal Pressure inlet direction ADP12**(*)
Dimensions
General tolerance: ±0.3 ±012
Recommended PC board pattern
( BOTTOM VIEW )
Tolerance: ±0.1 ±.004
Terminal connection diagram
Terminal No. | Name |
---|---|
1 | Output (-) |
2 | Power supply (+) |
3 | Output (+) |
4 | No connection |
5 | Power supply (-) |
6 | Output (-) |