Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Measurement Sensors > Measurement Sensors > Contact-Type Digital Displacement Sensor HG-S
|
Robust and slim body contributes to a longer service life
The optical absolute method eliminates “value skipping” and “unset zero point”!
|
CE
, UKCA
Approved
Please check "Communication Unit for Digital Displacement sensor SC-HG1" which can connect digital displacement sensor controller as well. |
Self-monitoring function released by using the digital displacement sensor communication unit SC-HG1 in combination with digital displacement sensor HG-S series and HG-T series.
>>HG-S / HG-T self-monitoring function
>>Communication Unit for Digital Displacement Sensors SC-HG1
Box type with an ultra-slim 11 mm 0.433 in width. Furthermore, the unit weighs only approx. 80 g. (Note 1)
Note 1: Values on the 10 mm 0.394 in type (HG-S1010□ / HG-S1110□)
A new structure supports the spindle with upper and lower plain bearings to significantly increase rigidity. Unlike ball bearings, these bearings efficiently disperse lateral loads on the spindle, significantly reducing the risk of breakage. |
A bending-resistant cable provides peace of mind even when the sensor is installed on a movable tool.
The sensor head can be changed safely without turning off the controller. This reduces the man-hours required for the change of line setup for processing of different workpieces, thus achieving a significant reduction of setup change time.
Spindle whirl-stop is accomplished by means of a metal guide requiring a several μm level assembly precision. Unlike a plastic guide, the risk of measurement error and glass scale breakage caused by deformation, wear, and other deterioration is significantly reduced. |
Displacement is measured by reading a glass scale with a different slit pattern at each reading position using a highresolution sensor. This eliminates "value skipping" even when measuring at high speed, and there is no concern of "unset zero point".
[40 μm 1.574 mil or less (typical value) on the HG-S1032 / HG-S1050 (Note 2)]
Tip deviation that reduces measurement precision is also minimized. Deviation of the measurement point is held to a minimum.
(Note 2) : | Value calculated from the clearance of the upper and lower plain bearings. |
---|
|
|
* In the case of the 10 mm 0.394 in type / 32 mm 1.260 in type |
Even if unexpected upward thrust occurs, the lower turning off the power supply part of the spindle blocks the impact. Damage to the internal structure, including the glass scale, is minimized.
Regular type
Original test was conducted to ensure durability against vertical sliding and lateral load that sensors are often subjected to in actual operations. There is a reason why you can use this product with peace of mind for a long time.
|
|
|
(Note 4) : | Value on the HG-S1010 / HG-S1110. |
---|---|
(Note 5) : | Button-type probe for evaluation purposes was installed on the test sample for the lateral load resistance test. |
* In the case of the HG-S1010 / HG-S1110 As of January 2021, in-company survey.
Air-driven type
|
|
|
|
The controller features the industry's first* dual display and offers versatile functions and excellent ease of use. It allows simple and reliable operation of the advanced measurement function in a diversity of applications.
* As a sensor product using optical absolute method, as of September 2015 (according
to in-company survey)
The 2-line digital display simultaneously shows head measurement (measured value) and judgment value (calculated value).
The high-contrast LCD provides sharp and clear indications and wide viewing angle.
Values between allowable maximum and minimum values are indicated in green. Values outside of the allowable range are indicated in orange. This provides at-a-glance understanding of the margin to the tolerance limits.
The selective copy function significantly reduces the man-hours required for initial setting and maintenance.
The following data is saved in the memory. The stored data can be used effectively for on-site analysis.
• Maximum peak value during operation
• Number of times maximum stroke was exceeded
• Cumulative spindle moving distance (m)
Alarm can be set to notify the user when upward thrust (stroke) exceeds the value set by the user.
Easy-to-understand 2-line digital display
Easy tolerance setting
Align with master workpiece and press ENTER key for easy tolerance setting.
No need for trigger input
Easy setting of time length from measurement start to measurement stabilization. Minimizes measurement fluctuation due to the vibration caused by stopping of spindle rotation. (1) Static width setting Stability range above the ST level can be set as desired. (2) Delay timer setting Desired delay time after measurement exceeding the ST level can be set. |
Lateral connection of slave units for added operational ease
One master unit can be connected with up to 15 slave units in any order. This allows easy multi-point calculations.
* When a digital displacement sensor communication unit is connected, a maximum of 14 slave units can be connected per master unit.
Controller variations
■Master unit (1 model)
・High performance type (analog current + input / output)
■Slave unit (3 models)
・High performance type (analog current + input / output)
・Standard type (input / output)
・Wire-saving type
|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)