| Series/Type |
Catalog |
Style |
Parts No |
Features |
Varistor Voltage |
Maximum Peak Current |
Information on RoHS compliance |
Related Information |
| - |
- |
- |
- |
- |
v |
A |
- |
- |

ZNR Transient/Surge Absorbers Type:D Series:E |
 |
 |
ERZE08Axxx ERZE11Axxx ERZE14Axxx
|
*Large withstanding surge current capability in compact sizes *Large Energy Handling Capability absorbing transient overvoltages in compact sizes *Wide range of varistor voltages
|
200 to 1100V
|
2500 to 10000
|
RoHS compliant (Please refer to the Related Information.)
|
 |
ZNR Transient/Surge Absorbers Type:D Series:V |
 |
 |
ERZV05Dxxxxx ERZV07Dxxxxx ERZV09Dxxxxx ERZV10Dxxxxx ERZV14Dxxxxx ERZV20Dxxxxx
|
*Standard type with radial leads for general surge protect applications *For Surge Pulse
|
18 to 1800V
|
125 to 10000
|
 |
ZNR Transient/Surge Absorbers SMD Type ,Series:HF |
 |
 |
ERZHF2M270
|
*For Automotive (DC12V) *Meet for Load Damp Surge *Maximum Surge:JASO A-1 70V 1time
|
27
|
|
 |
ZNR Transient/Surge Absorbers SMD Type ,Series:VF |
 |
 |
ERZVF1Mxxx ERZVF2Mxxx
|
*Surface mount type with protective coating so as to high leve; reliability *Surge Pulse
|
22 to 470
|
125 to 600 (at 8/20us)
|
 |
ZNR Transient/Surge Absorbers Type:SC |
 |
 |
ERZVS34Cxxx
|
*For incorporation in a surge protective device *corresponding to the IEC61643-1
|
200 to 950
|
ln 20kA lmax. 40kA(at 8/20us)
|
 |
ZNR Transient/Surge Absorbers Type:E |
 |
 |
ERZC20EKxxx ERZC32EKxxx
|
*Very large surge withstanding capability with a compact size *Direct mounting on boards like a power distribution board available *Fast response to steep impulse voltage
|
200 to 1100
|
5000 to 20000
|
 |
UL and CSA Recognized ZNR Surge Absorber with Tabs Type:CK |
 |
 |
ERZC32CKxxxW ERZC40CKxxxW
|
*UL and CSA recognized components *High energy handling capability (210 to 750 joules),Large withstanding peak current(25 to 30kA) *Common terminals for electrical connection and mounting
|
20 to 25
|
 |
ZNR transient/surge Absorbers Type:P |
 |
 |
ERZA20PK102 ERZA20PK251 ERZA20PK501
|
*Plug-in type with deterioration indicator *For application to industrial equipment
|
250 to 1000
|
5000 (at 8/20us)
|
 |
ZNR Transient/Surge Absorbers Type:J |
 |
 |
ERZA80JK112 ERZA80JK122 ERZA80JK561
|
Stack-type for heavy surge energy application(High power induced load and so on)
|
560 to 1250
|
|
 |
ZNR Transient/surge absorgers Type:G |
 |
 |
ERZA20GS173H ERZA20GS852H ERZA48GK502
|
For protection to switching surge of high voltage(3.3,6.6kV)equipment
|
5 to 17kV
|
21kA to 5000
|
RoHS compliant
|
- |
Surge Absorber Units |
 |
 |
ERZAxxxxxxx
|
Surge absorber with connected ZNRs and circuit breaker in box
|
22 to 1000
|
5000 to 50000
|
- |
ZNR Surge Absorbers, For Thyristor Protection Type:E.J |
 |
 |
ERZC20EKxxxP ERZC32EKxxxP ERZUxxJPxxx
|
Thristor protection against swithing surge transformer
|
510 to 2500
|
|
- |