Main Contents begins from here.
|


| Realization of high productivity High productivity achieved by elimination of head waiting time with the dual lane/dual head concept. For 570 ml (20 oz.) syringe specifications (option), the constant-viscosity support system has been built into the material supply unit, maintaining high accuracy and reducing down time for material replenishment. |
| Wide range of material/application coverage with 2 dispense head types. Selection of dispense heads allows dispensing of a high viscosity sealant to a low viscosity underfill material. Straight and curved lines can be drawn with the Continuous Path control. |
| Realization of stable application by automatic correction. Auto correction of nozzle-substrate position with the height sensor allows steady dispensing. Weight monitoring system calibrates dispensing volume automatically and maintains volume accuracy. (option) |
| Model ID | IPAC-DS | IPAC-DU |
| Model No. *1 | NM-EJM4C, NM-MH20 | NM-EJM5C, NM-MH30 |
| Carrier dimensions (mm) *2 | L 220 x W 29 to L 323 x W 146 | |
| Usage | Sealant | Underfill |
| Pump structure | Auger pump | Linear pump |
| Material supply (standard) | 170 ml (6 oz.) syringe | |
| Electric source | 3-phase AC 200 / 208 / 380 / 415 / 480 V, 1.5 kVA | 3-phase AC 200 / 208 / 380 / 415 / 480 V, 5.5 kVA *4 |
| Pneumatic source | 0.49 MPa, 60 L/min (A.N.R.) | |
| Dimensions (mm) *3 | W 980 x D 1 660 x H 1 650 | |
| Mass | 1 750 kg (Only for main body) | |